import esphome.codegen as cg
|
|
from esphome.components import sensor
|
|
import esphome.config_validation as cv
|
|
from esphome.const import (
|
|
CONF_ID,
|
|
DEVICE_CLASS_CURRENT,
|
|
DEVICE_CLASS_ENERGY,
|
|
DEVICE_CLASS_POWER,
|
|
DEVICE_CLASS_POWER_FACTOR,
|
|
DEVICE_CLASS_VOLTAGE,
|
|
STATE_CLASS_MEASUREMENT,
|
|
STATE_CLASS_TOTAL_INCREASING,
|
|
UNIT_AMPERE,
|
|
UNIT_VOLT,
|
|
UNIT_WATT,
|
|
UNIT_WATT_HOURS,
|
|
)
|
|
|
|
from .. import CONF_DLMS_METER_ID, DlmsMeterComponent
|
|
|
|
AUTO_LOAD = ["dlms_meter"]
|
|
|
|
CONFIG_SCHEMA = cv.Schema(
|
|
{
|
|
cv.GenerateID(CONF_DLMS_METER_ID): cv.use_id(DlmsMeterComponent),
|
|
cv.Optional("voltage_l1"): sensor.sensor_schema(
|
|
unit_of_measurement=UNIT_VOLT,
|
|
accuracy_decimals=1,
|
|
device_class=DEVICE_CLASS_VOLTAGE,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
),
|
|
cv.Optional("voltage_l2"): sensor.sensor_schema(
|
|
unit_of_measurement=UNIT_VOLT,
|
|
accuracy_decimals=1,
|
|
device_class=DEVICE_CLASS_VOLTAGE,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
),
|
|
cv.Optional("voltage_l3"): sensor.sensor_schema(
|
|
unit_of_measurement=UNIT_VOLT,
|
|
accuracy_decimals=1,
|
|
device_class=DEVICE_CLASS_VOLTAGE,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
),
|
|
cv.Optional("current_l1"): sensor.sensor_schema(
|
|
unit_of_measurement=UNIT_AMPERE,
|
|
accuracy_decimals=2,
|
|
device_class=DEVICE_CLASS_CURRENT,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
),
|
|
cv.Optional("current_l2"): sensor.sensor_schema(
|
|
unit_of_measurement=UNIT_AMPERE,
|
|
accuracy_decimals=2,
|
|
device_class=DEVICE_CLASS_CURRENT,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
),
|
|
cv.Optional("current_l3"): sensor.sensor_schema(
|
|
unit_of_measurement=UNIT_AMPERE,
|
|
accuracy_decimals=2,
|
|
device_class=DEVICE_CLASS_CURRENT,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
),
|
|
cv.Optional("active_power_plus"): sensor.sensor_schema(
|
|
unit_of_measurement=UNIT_WATT,
|
|
accuracy_decimals=0,
|
|
device_class=DEVICE_CLASS_POWER,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
),
|
|
cv.Optional("active_power_minus"): sensor.sensor_schema(
|
|
unit_of_measurement=UNIT_WATT,
|
|
accuracy_decimals=0,
|
|
device_class=DEVICE_CLASS_POWER,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
),
|
|
cv.Optional("active_energy_plus"): sensor.sensor_schema(
|
|
unit_of_measurement=UNIT_WATT_HOURS,
|
|
accuracy_decimals=0,
|
|
device_class=DEVICE_CLASS_ENERGY,
|
|
state_class=STATE_CLASS_TOTAL_INCREASING,
|
|
),
|
|
cv.Optional("active_energy_minus"): sensor.sensor_schema(
|
|
unit_of_measurement=UNIT_WATT_HOURS,
|
|
accuracy_decimals=0,
|
|
device_class=DEVICE_CLASS_ENERGY,
|
|
state_class=STATE_CLASS_TOTAL_INCREASING,
|
|
),
|
|
cv.Optional("reactive_energy_plus"): sensor.sensor_schema(
|
|
unit_of_measurement=UNIT_WATT_HOURS,
|
|
accuracy_decimals=0,
|
|
device_class=DEVICE_CLASS_ENERGY,
|
|
state_class=STATE_CLASS_TOTAL_INCREASING,
|
|
),
|
|
cv.Optional("reactive_energy_minus"): sensor.sensor_schema(
|
|
unit_of_measurement=UNIT_WATT_HOURS,
|
|
accuracy_decimals=0,
|
|
device_class=DEVICE_CLASS_ENERGY,
|
|
state_class=STATE_CLASS_TOTAL_INCREASING,
|
|
),
|
|
# Netz NOE
|
|
cv.Optional("power_factor"): sensor.sensor_schema(
|
|
accuracy_decimals=3,
|
|
device_class=DEVICE_CLASS_POWER_FACTOR,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
),
|
|
}
|
|
).extend(cv.COMPONENT_SCHEMA)
|
|
|
|
|
|
async def to_code(config):
|
|
hub = await cg.get_variable(config[CONF_DLMS_METER_ID])
|
|
|
|
sensors = []
|
|
for key, conf in config.items():
|
|
if not isinstance(conf, dict):
|
|
continue
|
|
id = conf[CONF_ID]
|
|
if id and id.type == sensor.Sensor:
|
|
sens = await sensor.new_sensor(conf)
|
|
cg.add(getattr(hub, f"set_{key}_sensor")(sens))
|
|
sensors.append(f"F({key})")
|
|
|
|
if sensors:
|
|
cg.add_define(
|
|
"DLMS_METER_SENSOR_LIST(F, sep)", cg.RawExpression(" sep ".join(sensors))
|
|
)
|