Co-authored-by: pre-commit-ci-lite[bot] <117423508+pre-commit-ci-lite[bot]@users.noreply.github.com> Co-authored-by: Copilot <175728472+Copilot@users.noreply.github.com> Co-authored-by: Jonathan Swoboda <154711427+swoboda1337@users.noreply.github.com> Co-authored-by: edenhaus <edenhaus@users.noreply.github.com> Co-authored-by: J. Nick Koston <nick@home-assistant.io> Co-authored-by: J. Nick Koston <nick+github@koston.org>
84 lines
2.4 KiB
Python
84 lines
2.4 KiB
Python
import esphome.codegen as cg
|
|
from esphome.components import number
|
|
import esphome.config_validation as cv
|
|
from esphome.const import CONF_STEP, DEVICE_CLASS_TEMPERATURE, UNIT_CELSIUS
|
|
|
|
from .. import (
|
|
CONF_MICRONOVA_ID,
|
|
MICRONOVA_ADDRESS_SCHEMA,
|
|
MicroNova,
|
|
MicroNovaListener,
|
|
micronova_ns,
|
|
register_micronova_writer,
|
|
to_code_micronova_listener,
|
|
)
|
|
|
|
ICON_FLASH = "mdi:flash"
|
|
|
|
CONF_THERMOSTAT_TEMPERATURE = "thermostat_temperature"
|
|
CONF_POWER_LEVEL = "power_level"
|
|
|
|
MicroNovaNumber = micronova_ns.class_(
|
|
"MicroNovaNumber", number.Number, MicroNovaListener
|
|
)
|
|
|
|
CONFIG_SCHEMA = cv.Schema(
|
|
{
|
|
cv.GenerateID(CONF_MICRONOVA_ID): cv.use_id(MicroNova),
|
|
cv.Optional(CONF_THERMOSTAT_TEMPERATURE): number.number_schema(
|
|
MicroNovaNumber,
|
|
unit_of_measurement=UNIT_CELSIUS,
|
|
device_class=DEVICE_CLASS_TEMPERATURE,
|
|
)
|
|
.extend(
|
|
MICRONOVA_ADDRESS_SCHEMA(
|
|
default_memory_location=0x20,
|
|
default_memory_address=0x7D,
|
|
is_polling_component=True,
|
|
)
|
|
)
|
|
.extend(
|
|
{
|
|
cv.Optional(CONF_STEP, default=1.0): cv.float_range(min=0.1, max=10.0),
|
|
}
|
|
),
|
|
cv.Optional(CONF_POWER_LEVEL): number.number_schema(
|
|
MicroNovaNumber,
|
|
icon=ICON_FLASH,
|
|
).extend(
|
|
MICRONOVA_ADDRESS_SCHEMA(
|
|
default_memory_location=0x20,
|
|
default_memory_address=0x7F,
|
|
is_polling_component=True,
|
|
)
|
|
),
|
|
}
|
|
)
|
|
|
|
|
|
async def to_code(config):
|
|
mv = await cg.get_variable(config[CONF_MICRONOVA_ID])
|
|
|
|
if thermostat_temperature_config := config.get(CONF_THERMOSTAT_TEMPERATURE):
|
|
register_micronova_writer()
|
|
numb = await number.new_number(
|
|
thermostat_temperature_config,
|
|
mv,
|
|
min_value=0,
|
|
max_value=40,
|
|
step=thermostat_temperature_config.get(CONF_STEP),
|
|
)
|
|
await to_code_micronova_listener(mv, numb, thermostat_temperature_config)
|
|
cg.add(numb.set_use_step_scaling(True))
|
|
|
|
if power_level_config := config.get(CONF_POWER_LEVEL):
|
|
register_micronova_writer()
|
|
numb = await number.new_number(
|
|
power_level_config,
|
|
mv,
|
|
min_value=1,
|
|
max_value=5,
|
|
step=1,
|
|
)
|
|
await to_code_micronova_listener(mv, numb, power_level_config)
|